AMSJ » Dangerous incident report
Incident Prevention/Mitigation LATEST NEWS MANAGING MINING RISKS

Dangerous incident report

dangerous incident

Dangerous incident

Summary: An underground mono pump stopped operating and upon inspection the electrician noticed smoke and a possible fire coming from the pulley belts that drive the pump. The electrician used an extinguisher to eliminate any fire, isolated the pump and notified the shift supervisor.
Recommendations to industry: Mine operators should review maintenance procedures including adjustments lifecycle management of drive belts in accordance with manufacturers recommendations on fixed plant installations.

Add Comment

Click here to post a comment